ISO conditions. Fuel* – natural gas, associated oil gas, liquid fuel | |
Gas turbine | GTE-25P/GTE-25PA |
Nominal power at generator terminals, MW | 23,0 / 25,5 |
Efficiency at generator terminals, % | 36,65 / 37,2 |
Nominal electric current frequency, Hz | 50 |
PT exit gas temperature, °С | 473 / 502 |
PT exit gas flow, kg/s | 76,7 / 78,3 |
Heat rate in a heat recovery cycle, Gcal/h | 26,10 / 28,9 |
Total fuel utilization factor @ t exh = 110 °С, % | 85,0 / 86,3 |
GT genset inlet fuel gas parameters: – pressure (gage), kgf/ cm2 | 42...45 |
GT genset inlet fuel gas parameters: – temperature range, °С | + 5...+ 90 |
Equivalent noise level during maintenance, max dBA | 80 |
GT genset lifetime: – MTBO, h | 25 000 |
GT genset lifetime: – total, h | 100 000 |
* - fuel composition shall be negotiated with UEC-Aviadvigatel
-
modular design – factory preassembled modules;
-
easy to install;
-
easy to maintain;
-
high reliability;
-
condition-based life extension possible.
Transportation
- by separate modules without any special hoisting equipment;
- by railway;
- by road;
- by water.
Siting
- indoors;
- outdoors on the prepared foundation.
Fuel*
- natural gas;
- associated oil gas;
- liquid fuel.
* - fuel composition shall be negotiated with UEC-Aviadvigatel
Oil and gas companies and other industries. See the Page “Perm GT Gensets at the Customers’ Sites” for more detailed information.
CONTACT DETAILS
Daniil D. Sulimov
Deputy General Designer – Chief Designer, Gas Turbines for Power Generation



Sergei G. Serovaev
Deputy Head of Business Development Department